Udvikling af flydense lågkonstruktioner til damvarmelagre: Slutrapport for UVE-projektet "Lågkonstruktioner til damvarmelagre - Fase II" : Slutrapport for UVE-projektet "lågkonstruktioner til damvarmelagre - Fase 2"

From

Department of Buildings and Energy, Technical University of Denmark1

Department of Civil Engineering, Technical University of Denmark2

Experience collected during designing and construction of various types of floating covers for heat storage ground reservoirs is summarized. Economic calculations proved plastic covers to be generally cheaper than steel ones. On the other hand steel covers opposite to plastic ones can stand very high temperatures in a long time.

Thermo technical tests proved the annual heat losses through a 12100 m"2 cover to be between 500 and 626 MWh/year. Cold-bridge effect between the cover sections and storage reservoir edge are negligible. In phase III of this project the prototypes of these pilot-scale solutions will be tested in full scale.

Water- and vapor- proofing, moisture and water intrusion into insulation, motion of covers due to thermal expansion, mounting time and handling of covers will be tested. (EG).

Language: Danish
Publisher: Technical University of Denmark, Department of Civil Engineering
Year: 1998
Volume: 23
Pages: 57 s. + bilag.
Series: Ibe-rapport. R
ISBN: 8778770246 and 9788778770240
Types: Printed book and Report