This report documents DTU’s verification of a client load measurement system including calibrations installed on a given turbine at DTU test facility in Denmark. The load measurements will be carried out in a period and verification of measured loads from this period is not included in this report. The client is responsible for the measurement system and have documented this including calibrations in a number of reports, see section 3.
The verification is carried out in accordance to internal procedure which is a part of DTU Wind accredited quality system. The verification consist of a control of a chosen number of sensors and calibrations. DTU is as an accredited test laboratory with this report verifying that the client is carrying out the load measurements in accordance to Ref. [1].