High-resolution transmission measurements of CO2 at high temperatures for industrial applications

From

Department of Chemical and Biochemical Engineering, Technical University of Denmark1

CHEC Research Centre, Department of Chemical and Biochemical Engineering, Technical University of Denmark2

High-resolution transmission spectra of CO2 in the 2.7,4.3 and 15 μm regions at temperatures up to 1773 K and at approximately atmospheric pressure (1.00 ± 0.01atm) are measured and compared with line-by-line calculations based on the HITEMP-1995, HITEMP-2010, CDSD-HITEMP and CDSD-4000 databases. The spectra have been recorded in a high-temperature flow gas cell and using a Fourier transform infrared (FTIR) spectrometer at a nominal resolution of 0.125 cm-1.

The volume fractions of CO2 in the measurements were 1,10 and 100%. The measurements have been validated by comparison with medium-resolution data obtained by Bharadwaj and Modest [6]. The deviations between the experimental spectra and the calculations at 1773 K and the vibrational energy exchange and thermal dissociation of CO2 at high temperatures are discussed.

Language: English
Year: 2012
Pages: 2222-2233
ISSN: 18791352 and 00224073
Types: Journal article
DOI: 10.1016/j.jqsrt.2012.07.015
ORCIDs: Fateev, Alexander and Clausen, Sønnik