A High-Throughput SU-8 Microfluidic Magnetic Bead Separator

In Transducers '07, 14th International Conference on Solid-state Sensors, Actuators and Microsystems — 2007, pp. 1773-1776
From

Cell Particle Handling, Department of Micro- and Nanotechnology, Technical University of Denmark1

Department of Micro- and Nanotechnology, Technical University of Denmark2

Magnetic Systems, Department of Micro- and Nanotechnology, Technical University of Denmark3

We present a novel microfluidic magnetic bead separator based on SU-8 fabrication technique for high through-put applications. The experimental results show that magnetic beads can be captured at an efficiency of 91 % and 54 % at flow rates of 1 mL/min and 4 mL/min, respectively. Integration of soft magnetic elements in the chip leads to a slightly higher capturing efficiency and a more uniform distribution of captured beads over the separation chamber than the system without soft magnetic elements.

Language: English
Publisher: IEEE
Year: 2007
Pages: 1773-1776
Proceedings: 14th International Solid-State Sensors, Actuators and Microsystems Conference
ISBN: 1424408415 , 1424408423 , 150908228X , 150908228x , 9781424408412 , 9781424408429 and 9781509082285
Types: Conference paper
DOI: 10.1109/SENSOR.2007.4300497
ORCIDs: Bu, Minqiang , Wolff, Anders and Hansen, Mikkel Fougt