About

Log in?

DTU users get better search results including licensed content and discounts on order fees.

Anyone can log in and get personalized features such as favorites, tags and feeds.

Log in as DTU user Log in as non-DTU user No thanks

DTU Findit

Conference paper

Acoustic conditions of clinic rooms for sound field audiometry

In Proceedings of 23rd International Congress on Acoustics — 2019, pp. 4654-59
From

Acoustic Technology, Department of Electrical Engineering, Technical University of Denmark1

Department of Electrical Engineering, Technical University of Denmark2

Technical University of Denmark3

Korea Research Institute of Standards and Science4

Saint-Gobain S.A.5

Interacoustics A/S6

The British Society of Audiology (BSA) recommends a maximum reverberation time of 0.25 s for sound field audiometry in clinic rooms. The present study measured room impulse responses from 36 rooms where sound field audiometry is conducted in Denmark, Germany and the Republic of Korea. The volumes of the rooms measured ranged from 14 m3 to 60 m3, and the reverberation times ranged from 0.1 s to 0.65 s.

Their background noise levels varied from 20 dBA to 30 dBA. Office type rooms where other medical tasks also take place generally lack sound absorption particularly at low frequencies. Other acoustical parameters such as clarity and definition are also presented.

Language: English
Publisher: Deutsche Gesellschaft für Akustik
Year: 2019
Pages: 4654-59
Proceedings: 23rd International Congress on AcousticsInternational Congress on Acoustics
ISBN: 3939296155 and 9783939296157
Types: Conference paper
ORCIDs: Jeong, Cheol-Ho

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis