About

Log in?

DTU users get better search results including licensed content and discounts on order fees.

Anyone can log in and get personalized features such as favorites, tags and feeds.

Log in as DTU user Log in as non-DTU user No thanks

DTU Findit

Report

The response of a neutron rem counter to thermal, to intermediate-energy, and to fast neutrons

From

Risø National Laboratory for Sustainable Energy, Technical University of Denmark1

A neutron recounter (Studsvik type 2202D) was calibrated at a number of neutron energies during a technical seminar on neutron dosimetry ii. radiation protection sponsored by the Commission of the European Communities and held at the Physikalisch-Technische Bundesanstalt in Braunschweig. The rem counter was calibrated using 1) monoenergetic neutrons of eight different energies between 100 keV and 19 MeV produced by means of an accelerator, 2) neutrons from three-Radioactive neutron sources (Ra-Be, Am-Be and 252Cf), and 3) a thermal-neutron beam and two filtered neutron beams (2 and 2k.3 keV, respectively) from a reactor.

The results show that the sensitivity of the rem counter follows the "ICRP rem curve within about - 20 % at neutron energies between 250 keV and 5 MeV. However, at neutron energies below 100 keV and above 10 MeV the sensitivity deviates significantly from the "ICRP rem curve". When calibrated at, say, 1 MeV, the rem counter will overestimate the dose equivalent in radiation fields where a significant portion of the dose equivalent is due to neutrons of energies between 100 eV and 100 keV, and it will underestimate the dose equivalent from thermal neutrons and from neutrons of energies above 10 MeV.

Language: English
Publisher: Risø National Laboratory
Year: 1978
Series: Risø-m
ISBN: 8755005225 and 9788755005228
ISSN: 04186435
Types: Report