About

Log in?

DTU users get better search results including licensed content and discounts on order fees.

Anyone can log in and get personalized features such as favorites, tags and feeds.

Log in as DTU user Log in as non-DTU user No thanks

DTU Findit

Journal article

A sampling approach for predicting the eating quality of apples using visible–near infrared spectroscopy : Predicting apple quality using visible-NIR spectroscopy

From

University of Copenhagen1

Department of Applied Mathematics and Computer Science, Technical University of Denmark2

Statistics and Data Analysis, Department of Applied Mathematics and Computer Science, Technical University of Denmark3

Dayenú4

BACKGROUND Visible–near infrared spectroscopy remains a method of increasing interest as a fast alternative for the evaluation of fruit quality. The success of the method is assumed to be achieved by using large sets of samples to produce robust calibration models. In this study we used representative samples of an early and a late season apple cultivar to evaluate model robustness (in terms of prediction ability and error) on the soluble solids content (SSC) and acidity prediction, in the wavelength range 400–1100 nm.

RESULTS A total of 196 middle–early season and 219 late season apples (Malus domestica Borkh.) cvs ‘Aroma’ and ‘Holsteiner Cox’ samples were used to construct spectral models for SSC and acidity. Partial least squares (PLS), ridge regression (RR) and elastic net (EN) models were used to build prediction models.

Furthermore, we compared three sub-sample arrangements for forming training and test sets (‘smooth fractionator’, by date of measurement after harvest and random). Using the ‘smooth fractionator’ sampling method, fewer spectral bands (26) and elastic net resulted in improved performance for SSC models of ‘Aroma’ apples, with a coefficient of variation CVSSC = 13%.

The model showed consistently low errors and bias (PLS/EN: R2cal = 0.60/0.60; SEC = 0.88/0.88°Brix; Biascal = 0.00/0.00; R2val = 0.33/0.44; SEP = 1.14/1.03; Biasval = 0.04/0.03). However, the prediction acidity and for SSC (CV = 5%) of the late cultivar ‘Holsteiner Cox’ produced inferior results as compared with ‘Aroma’.

CONCLUSION It was possible to construct local SSC and acidity calibration models for early season apple cultivars with CVs of SSC and acidity around 10%. The overall model performance of these data sets also depend on the proper selection of training and test sets. The ‘smooth fractionator’ protocol provided an objective method for obtaining training and test sets that capture the existing variability of the fruit samples for construction of visible–NIR prediction models.

The implication is that by using such ‘efficient’ sampling methods for obtaining an initial sample of fruit that represents the variability of the population and for sub-sampling to form training and test sets it should be possible to use relatively small sample sizes to develop spectral predictions of fruit quality.

Using feature selection and elastic net appears to improve the SSC model performance in terms of R2, RMSECV and RMSEP for ‘Aroma’ apples. © 2013 Society of Chemical Industry

Language: English
Publisher: John Wiley & Sons, Ltd
Year: 2013
Pages: 3710-3719
ISSN: 04493257 , 00225142 and 10970010
Types: Journal article
DOI: 10.1002/jsfa.6207
ORCIDs: Clemmensen, Line Katrine Harder , 0000-0002-5993-3062 and 0000-0002-8602-4657

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis