Conference paper
Differential thermal analysis microsystem for explosive detection
Nanoprobes Group, NanoSystemsEngineering Section, Department of Micro- and Nanotechnology, Technical University of Denmark1
NanoSystemsEngineering Section, Department of Micro- and Nanotechnology, Technical University of Denmark2
Department of Micro- and Nanotechnology, Technical University of Denmark3
A micro differential thermal analysis (DTA) system is used for detection of trace explosive particles. The DTA system consists of two silicon micro chips with integrated heaters and temperature sensors. One chip is used for reference and one for the measurement sample. The sensor is constructed as a small silicon nitride membrane incorporating heater elements and a temperature measurement resistor.
In this manuscript the DTA system is described and tested by measuring calorimetric response of 3 different kinds of explosives (TNT, RDX and PETN). This project is carried out under the framework of the Xsense project at the Technical University of Denmark (DTU) which combines four independent sensing techniques, these micro DNT sensors will be included in handheld explosives detectors with applications in homeland security and landmine clearance.
Language: | English |
---|---|
Year: | 2011 |
Pages: | 80312P-6 |
Proceedings: | Micro- and Nanotechnology Sensors, Systems, and Applications III |
ISSN: | 1996756x and 0277786x |
Types: | Conference paper |
DOI: | 10.1117/12.883960 |
ORCIDs: | Boisen, Anja |