About

Log in?

DTU users get better search results including licensed content and discounts on order fees.

Anyone can log in and get personalized features such as favorites, tags and feeds.

Log in as DTU user Log in as non-DTU user No thanks

DTU Findit

Journal article

Reducing burden of disease from residential indoor air exposures in Europe (HEALTHVENT project)

From

National Institute for Health and Welfare1

University of Milan2

European Commission Joint Research Centre Institute3

University of Porto4

Department of Civil Engineering, Technical University of Denmark5

Section for Indoor Climate and Building Physics, Department of Civil Engineering, Technical University of Denmark6

Background: The annual burden of disease caused indoor air pollution, including polluted outdoor air used to ventilate indoor spaces, is estimated to correspond to a loss of over 2 million healthy life years in the European Union (EU). Based on measurements of the European Environment Agency (EEA), approximately 90 % of EU citizens live in areas where the World Health Organization (WHO) guidelines for air quality of particulate matter sized <2.5 mm (PM2.5) are not met.

Since sources of pollution reside in both indoor and outdoor air, selecting the most appropriate ventilation strategy is not a simple and straightforward task. Methods: A framework for developing European health-based ventilation guidelines was created in 2010–2013 in the EU-funded HEALTHVENT project.

As a part of the project, the potential efficiency of control policies to health effects caused by residential indoor exposures of fine particulate matter (PM2.5), outdoor bioaerosols, volatile organic compounds (VOC), carbon oxide (CO) radon and dampness was estimated. The analysis was based on scenario comparison, using an outdoor-indoor mass-balance model and varying the ventilation rates.

Health effects were estimated with burden of diseases (BoD) calculations taking into account asthma, cardiovascular (CV) diseases, acute toxication, respiratory infections, lung cancer and chronic obstructive pulmonary disease (COPD). Results: The quantitative comparison of three main policy approaches, (i) optimising ventilation rates only; (ii) filtration of outdoor air; and (iii) indoor source control, showed that all three approaches are able to provide substantial reductions in the health risks, varying from approximately 20 % to 44 %, corresponding to 400 000 and 900 000 saved healthy life years in EU-26.

PM2.5 caused majority of the health effects in all included countries, but the importance of the other pollutants varied by country. Conclusions: The present modelling shows, that combination of controlling the indoor air sources and selecting appropriate ventilation rate was the most effective to reduce health risks.

If indoor sources cannot be removed or their emissions cannot be limited to an accepted level, ventilation needs to be increased to remove remaining pollutants. In these cases filtration of outdoor air may be needed to prevent increase of health risks.

Language: English
Publisher: BioMed Central
Year: 2016
Pages: 61-72
Proceedings: The 11th International Conference on Urban Health
ISSN: 1476069x
Types: Journal article
DOI: 10.1186/s12940-016-0101-8
ORCIDs: Wargocki, Pawel

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis