About

Log in?

DTU users get better search results including licensed content and discounts on order fees.

Anyone can log in and get personalized features such as favorites, tags and feeds.

Log in as DTU user Log in as non-DTU user No thanks

DTU Findit

Journal article

In-line whole blood fractionation for Raman analysis of blood plasma

In Analyst 2019, Volume 144, Issue 2, pp. 602-610
From

Department of Health Technology, Technical University of Denmark1

Optofluidics, Nano and Bio-physical Systems, Department of Health Technology, Technical University of Denmark2

Nano and Bio-physical Systems, Department of Health Technology, Technical University of Denmark3

Nanofluidics and Bioimaging, Nano and Bio-physical Systems, Department of Health Technology, Technical University of Denmark4

Blood plasma evaluation has high significance in clinical diagnostics. Current schemes involve the preparation of blood plasma by centrifugation of whole blood followed by electrochemical or spectroscopic analysis. However, centrifugation is often too time-consuming for application in clinical emergency and point-of-care settings.

We propose to combine microfluidic, instantaneous plasma fractionation with localized spectroscopic methods for in-line analysis. As an example, we present confocal Raman spectroscopy in fractionated plasma domains at two different Raman excitation wavelengths. Resonance Raman spectroscopy with laser excitation at 408 nm allows the specific detection of free hemoglobin in blood plasma at concentrations above 22 mg dl-1 (level of detection).

Consequently, we are able to accurately resolve the range of clinical relevance regarding hemolysis. At near-infrared excitation (785 nm) we furthermore demonstrate the acquisition of characteristic Raman spectra of fractionated blood plasma in the microfluidic setting. These spectra can serve as starting point for a multi-parameter regression analysis to quantify a set of blood plasma parameters from a single Raman spectrum.

The combined microfluidics and Raman spectroscopy method is non-destructive and has a whole blood consumption of less than 100 μl per hour. It thus allows for continuous in-line blood plasma monitoring.

Language: English
Publisher: The Royal Society of Chemistry
Year: 2019
Pages: 602-610
ISSN: 13645528 and 00032654
Types: Journal article
DOI: 10.1039/c8an01197d
ORCIDs: Zhu, Xiaolong , Marie, Rodolphe , Kristensen, Anders and 0000-0001-9887-2533

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis