Comparison of Antenna Measurement Facilities with the DTU-ESA 12 GHz Validation Standard Antenna within the EU Antenna Centre of Excellence

From

Electromagnetic Systems, Department of Electrical Engineering, Technical University of Denmark1

Department of Electrical Engineering, Technical University of Denmark2

National Autonomous University of Mexico3

Polytechnic University of Catalonia4

Orange Labs5

SAAB Microwave Systems AB6

RUAG Space AB7

The primary objective of many antenna measurement facilities is to provide a specified high accuracy of the measured data. The validation of an antenna measurement facility is the process of proving that such a specified accuracy can be achieved. Since this constitutes a very challenging task, antenna measurement accuracy has been the subject of much research over many years and a range of useful measures have been introduced.

Facility comparisons, together with antenna standards, error budgets, facility accreditations, and measurement procedure standards, constitute an effective measure towards facility validations. This paper documents the results of a comparison between 8 European antenna measurement facilities with a specially designed reference antenna, the DTU-ESA 12 GHz Validation Standard Antenna (VAST-12).

The electrical and mechanical properties of the VAST-12 antenna are presented and its three different coordinate systems are defined. The primary objective of the comparison is to obtain experience and results that can serve to develop standards for validation of antenna measurement facilities. The paper focuses on the comparison of the radiation pattern and presents not only the measurement data obtained at the facilities, but also investigates several procedures for comparing these data.

This includes various definitions of pattern difference and statistical measures as well as a reference pattern. The comparison took place in 2004-2005 as part of the European Union network of excellence called ACE-Antenna Centre of Excellence.

Language: English
Publisher: IEEE
Year: 2009
Pages: 1863-1878
ISSN: 15582221 and 0018926x
Types: Journal article
DOI: 10.1109/TAP.2009.2021934