Accuracy assessment of an industrial actuator

In Procedia C I R P 2016, Volume 62, pp. 417-422
From

Department of Mechanical Engineering, Technical University of Denmark1

Manufacturing Engineering, Department of Mechanical Engineering, Technical University of Denmark2

Polytechnic University of Turin3

A commercial linear actuator equipped with a 0.1 μm resolution encoder was used as a contact displacement sensor with adjustable force. The accuracy of the position reading of the actuator was evaluated from experimental data taking into account the uncertainty contributions. The tests consisted of length measurements of grade 0 steel gauge blocks.

Measurements with different values of contact force were performed to assess its influence. A statistical analysis of the experimental data was performed to support the accuracy assessment. Systematic effects were identified and corrected. An expanded uncertainty (k=2) lower than 1 μm was estimated.

Language: English
Year: 2016
Pages: 417-422
Proceedings: 10th CIRP Conference on Intelligent Computation in Manufacturing Engineering (CIRP ICME '16)
ISSN: 22128271
Types: Conference paper and Journal article
DOI: 10.1016/j.procir.2016.06.119
ORCIDs: Dalla Costa, Giuseppe , De Chiffre, Leonardo and Hansen, Hans Nørgaard