About

Log in?

DTU users get better search results including licensed content and discounts on order fees.

Anyone can log in and get personalized features such as favorites, tags and feeds.

Log in as DTU user Log in as non-DTU user No thanks

DTU Findit

Journal article

Extensive Evaluation of a Diffusion Denuder Technique for the Quantification of Atmospheric Stable and Radioactive Molecular Iodine

From

Institute of Inorganic and Analytical Chemistry, Johannes Gutenberg-University of Mainz, Duesbergweg 10-14, D-55128 Mainz, Germany, and Radiation Research Department, Risø National Laboratory, NUK-202, Technical University of Denmark, DK-4000 Roskilde, Denmark

In this paper we present the evaluation and optimization of a new approach for the quantification of gaseous molecular iodine (I2) for laboratory- and field-based studies and its novel application for the measurement of radioactive molecular iodine. α-Cyclodextrin (α-CD) in combination with 129I− is shown to be an effective denuder coating for the sampling of gaseous I2 by the formation of an inclusion complex.

The entrapped 127I2 together with the 129I− spike in the coating is then released and derivatized to 4-iodo-N,N-dimethylaniline (4-I-DMA) for gas chromatography−mass spectrometry (GC-MS) analysis. The 127I2 collected can be differentiated from the 129I− spike by MS. A set of parameters affecting the analytical performances of this approach, including amount of α-CD and 129I− applied, denuder length, sampling gas flow rate and sampling duration, relative humidity, sample storage period, and condition of release and derivatization of iodine, is extensively evaluated and optimized.

The collection efficiency is larger than 98% and the limit of detection (LOD) obtained is 0.17 parts-per-trillion-by-volume (pptv) for a sampling duration of 30 min at 500 mL min−1. Furthermore, the potential use of this protocol for the determination of radioactive I2 at ultra trace level is also demonstrated when 129I− used in the coating is replaced by 127I− and a multiple denuder system is used.

Using the present method we observed 25.7−108.6 pptv 127I2 at Mweenish Bay, Ireland and 108 molecule m−3 129I2 at Mainz, Germany.

Language: English
Publisher: American Chemical Society
Year: 2010
Pages: 5061-5066
ISSN: 15205851 and 0013936x
Types: Journal article
DOI: 10.1021/es100395p

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis