Journal article

Electro-ultrafiltration of industrial enzyme solutions

From

Department of Chemistry, Technical University of Denmark1

Department of Civil Engineering, Technical University of Denmark2

Computer Aided Process Engineering Center, Department of Chemical and Biochemical Engineering, Technical University of Denmark3

Department of Chemical and Biochemical Engineering, Technical University of Denmark4

To reduce the problems with fouling and concentration polarization during crossflow ultrafiltration of industrial enzyme solutions an electric field is applied across the membrane. The filtration performance during electro-ultrafiltration (EUF) has been tested with several enzymes. Results show that EUF is an effective method to filter high concentrated solutions at low crossfiow.

The flux improved 3-7 times for enzymes with a significant surface charge at an electric field strength of 1600V/m compared to conventional UF. The greatest improvement is observed at high concentration. Not all enzymes can be filtered with EUF, mainly due to a low surface charge and impurities in the feed solution.

Using a pulsed electric field did not improve the flux compared to a constant field. Gel electrophoresis experiments of the enzymes appear to be a useful method for estimating the influence of the electric field.

Language: English
Year: 2007
Pages: 28-37
ISSN: 18733123 and 03767388
Types: Journal article
DOI: 10.1016/j.memsci.2007.04.021