Estimating Building Airtightness from Data-A Case Study

From

Department of Applied Mathematics and Computer Science, Technical University of Denmark1

Dynamical Systems, Department of Applied Mathematics and Computer Science, Technical University of Denmark2

Department of Civil Engineering, Technical University of Denmark3

Energy and Services, Department of Civil Engineering, Technical University of Denmark4

The focus on energy conservation in buildings is increasing. Despite that, the yearly building renovation rate is only at around 1 %. To increase the renovation rate, new and time-efficient methods used for screening of large building portfolios' energy saving potential are needed. In this paper, a re-engineered take on the classical energy signature method is applied to two renovated apartments in Denmark.

The energy signature model relies on time-series measurements of space heat consumption, outdoor temperature, solar irradiation, and wind speed. The estimates obtained from it consist of-among other things-heat loss coefficient and wind-induced heat loss. This paper focuses on the latter. To validate the model estimate, the airtightness has been quantified by blower door-tests in both apartments: the results showed that one apartment is reasonable airtight, while the other suffers from significant air leakages.

The energy signature and two other infiltration models, based on blower door test results, were compared. Good agreement between the results obtained from the data-driven energy signature and the blower door test were found. With use of a simple linear relation between the average infiltration and the blower door test result (q50), from the Danish national building code, the energy signature was found to overestimate the blower door test result (q50) by 33 % for the leaky apartment and underestimate the same air flow by 18 % for the other apartment.

Both estimates are within the standard error of the infiltration model in the Danish national building code.

Language: English
Publisher: EDP Sciences
Year: 2021
Pages: 10004
Proceedings: Cold Climate HVAC & Energy 2021
ISSN: 22671242 and 25550403
Types: Journal article
DOI: 10.1051/e3sconf/202124610004
ORCIDs: Rasmussen, Christoffer , Hviid, Christian Anker , Bacher, Peder , Calí, Davide and Madsen, Henrik

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis