Department of Electrical Engineering, Technical University of Denmark1

The agreement obtained between measured breakdown voltages and predicted breakdown values is frequently used as a means of assessing the validity of the theory/model in question. However, owing to the mathematical nature of exponential growth, it is easy to formulate a criterion that provides acceptable breakdown values, although the criterion may contain totally unrealistic features.

An example from the work of A. Pedersen (1989) showing unrestricted exponential growth in SF 6 is used to highlight the insensitivity of breakdown voltages with respect to modeling

Language: English
Publisher: IEEE
Year: 1991
Pages: 378-379