Calculation of heat rating and burn-up for test fuel pins irradiated in DR3

From

Risø National Laboratory for Sustainable Energy, Technical University of Denmark1

A summary of the DR3 reactor and HP1 rig design is given followed by a detailed description of the calculation procedure for obtaining linear heat rating and burn-up values of fuel pins irradiated in HP1 rigs. The calculations are carried out rather detailed, especially regarding features like end pellet contribution to power as a function of burn-up, gamma heat contributions, and evaluation of local values of heat rating and burn-up.

Included in the report is also a description of the fast flux- and cladding temperature calculation techniques currently used. A good agreement between measured and calculated local burn-up values is found. This gives confidence to the detailed treatmant of the data.

Language: English
Publisher: Risø National Laboratory
Year: 1980
Series: Risø-m
ISBN: 8755006558 and 9788755006553
ISSN: 04186435
Types: Report