Conference paper
An Automated System for the Detection and Diagnosis of Kidney Lesions in Children from Scintigraphy Images
Designing a system for computer aided diagnosis is a complex procedure requiring an understanding of the biology of the disease, insight into hospital workflow and awareness of available technical solutions. This paper aims to show that a valuable system can be designed for diagnosing kidney lesions in children and adolescents from 99mTc- DMSA scintigraphy images.
We present the chain of analysis and provide a discussion of its performance. On a per-lesion basis, the classification reached an ROC-curve area of 0.96 (sensitivity/specificity e.g. 97%/85%) measured using an independent test group consisting of 56 patients with 730 candidate lesions. We conclude that the presented system for diagnostic support has the potential of increasing the quality of care regarding this type of examination.
Language: | English |
---|---|
Publisher: | Springer |
Year: | 2011 |
Pages: | 489-500 |
Proceedings: | 17th Scandinavian Conference on Image Analysis (SCIA) |
Series: | Lecture Notes in Computer Science |
Journal subtitle: | 17th Scandinavian Conference, Scia 2011 - Ystad, Sweden, May 2011 - Proceedings |
ISBN: | 3642212263 , 3642212271 , 9783642212260 and 9783642212277 |
ISSN: | 16113349 and 03029743 |
Types: | Conference paper |
DOI: | 10.1007/978-3-642-21227-7_46 |