Biomass Suspension Combustion: Effect of Two-Stage Combustion on NOx Emissions in a Laboratory-Scale Swirl Burner

From

CHEC Research Centre, Department of Chemical and Biochemical Engineering, Technical University of Denmark1

Department of Chemical and Biochemical Engineering, Technical University of Denmark2

A systematic study was performed in a suspension fired 20 kW laboratory-scale swirl burner test rig for combustion of biomass and co-combustion of natural gas and biomass. The main focus is put on the effect of two-stage combustion on the NO emission, as well as its effect on the incomplete combustion.

When two-stage combustion was applied, the NO emission level can be significantly reduced. The experimental results show that an optimal first-stage combustion stoichiometry (λ1) exists, at which a minimum NO emission can be achieved. An optimal stoichiometry of around 0.8 in the fuel-rich zone exists with respect to minimizing NO emissions.

When using wood and straw as co-firing fuels, 15−25% of the fuel-N is converted to NO. Straw appears to give the lowest conversion of fuel-N to NO. The results indicate that the optimal stoichiometry in the fuel-rich (λ1) zone for gaining the lowest NO may result from the homogeneous reaction, by comparing the NO emissions when firing natural gas with NH3 addition and co-firing natural gas and biomass.

The experimental results also show no significant increase of incomplete combustion of gas and char by applying optimized two-stage combustion.

Language: English
Year: 2009
Pages: 1398-1405
ISSN: 15205029 and 08870624
Types: Journal article
DOI: 10.1021/ef8004866
ORCIDs: Lin, Weigang , Jensen, Peter Arendt and Jensen, Anker Degn