About

Log in?

DTU users get better search results including licensed content and discounts on order fees.

Anyone can log in and get personalized features such as favorites, tags and feeds.

Log in as DTU user Log in as non-DTU user No thanks

DTU Findit

Journal article · Preprint article

Planck early results. VI. The High Frequency Instrument data processing

By Colley, J.-M.; Bartlett, J.G.; Bucher, M.; Cardoso, J.-F.; Castex, G.; Catalano, A.; Colley, J.-M.; Cressiot, C.; Delabrouille, J.; Ganga, K.; Giraud-Héraud, Y.; Kaplan, J.; Le Jeune, M.; Patanchon, G.; Piat, M.; Remazeilles, M.; Rosset, C.; Roudier, G.; Stompor, R.; Ashdown, M.; Hills, R.; Hobson, M.; Lasenby, A.; Stolyarov, V.; Kneissl, R.; Bond, J.R.; Miville-Deschênes, M.-A.; Banday, A.J.; Bernard, J.-P.; Forni, O.; Giard, M.; Leroy, C.; Marshall, D.J.; Montier, L.; Pointecouteau, E.; Ristorcelli, I.; Bock, J.J.; Doré, O.; Helou, G.; Hildebrandt, S.R.; Matsumura, T.; Pearson, T.J.; Prézeau, G.; Rocha, G.; Challinor, A.; Shellard, P.; Melin, J.-B.; Starck, J.-L.; Yvon, D.; Nørgaard-Nielsen, Hans Ulrik1,2; Kunz, M.; Marleau, F.; Netterfield, C.B.; Chiang, C.; Jones, W.C.; Knox, L.; Wandelt, B.D.; Dunkley, J.; De Bernardis, P.; Masi, S.; Nati, F.; Piacentini, F.; Bersanelli, M.; Kneissl, R.; Tauber, J.A.; Zacchei, A.; Mandolesi, N.; Bersanelli, M.; Guyot, G.; Désert, F.-X.; Chamballu, A.; Clements, D.L.; Jaffe, A.H.; Mortlock, D.; Novikov, D.; Rowan-Robinson, M.; Chary, R.-R.; Chen, X.; Ganga, K.; Lange, A.E.; McGehee, P.; Pearson, T.J.; Rusholme, B.; Benoît, A.; Aghanim, N.; Aumont, J.; Boulanger, F.; Dole, H.; Douspis, M.; Gispert, R.; Kunz, M.; Lagache, G.; Leroy, C.; Mercier, C.; Miville-Deschênes, M.-A.; Noviello, F.; Pajot, F.; Ponthieu, N.; Puget, J.-L.; Torre, J.-P.; Vibert, L.; Benabed, K.; Bouchet, F.R.; Cardoso, J.-F.; Colombi, S.; Delouis, J.-M.; Hivon, E.; Lesgourgues, J.; Moneti, A.; Prunet, S.; Riazuelo, A.; Sygnet, J.-F.; Wandelt, B.D.; Fosalba, P.; Wiesemeyer, H.; Thum, C.; Challinor, A.; Efstathiou, G.; Gratton, S.; Harrison, D.; Sutton, D.; Van Leeuwen, F.; Hildebrandt, S.R.; Bartlett, J.G.; Bock, J.J.; Crill, B.P.; Doré, O.; Górski, K.M. Holmes, W.A.; Lawrence, C.R.; Mitra, S.; Prézeau, G.; Rocha, G.; Saha, R.; Wade, L.A.; Maffei, B.; Ashdown, M.; Challinor, A.; Gratton, S.; Harrison, D.; Lasenby, A.; MacTavish, C.J.; Sutton, D.; Catalano, A.; Coulais, A.; Lamarre, J.-M.; Arnaud, M.; Starck, J.-L.; Cardoso, J.-F.; Vibert, D.; Girard, D.; Hildebrandt, S.R.; MacÍas-Pérez, J.F.; Perotto, L.; Renault, C.; Santos, D.; Ansari, R.; Couchot, F.; Filliard, C.; Haissinski, J.; Henrot-Versillé, S.; Lavabre, A.; Perdereau, O.; Plaszczynski, S.; Touze, F.; Tristram, M.; Borrill, J.; Banday, A.J.; Bartelmann, M.; Dolag, K.; Hernández-Monteagudo, C.; Sunyaev, R.; White, S.D.M.; McAuley, I.; Murphy, A.; Peacocke, T.; Yurchenko, V.; Crill, B.P.; Savini, G.; Bradshaw, T.; Crook, M.; Mann, R.; Ade, P.A.R.; Griffin, M.; North, C.; Spencer, L.; Sudiwala, R.; Woodcraft, A.; Sunyaev, R.; Borrill, J.; Church, S.; Osborne, S.; Bartelmann, M.; Schaefer, B.M.; Banday, A.J.; Bernard, J.-P.; Forni, O.; Giard, M.; Leroy, C.; Marshall, D.J.; Montier, L.; Pointecouteau, E.; Ristorcelli, I.; Reach, W.T.; Battaner, E.; Huffenberger, K.M.; Górski, K.M. ...and 197 more

From

Astrophysics, National Space Institute, Technical University of Denmark1

National Space Institute, Technical University of Denmark2

We describe the processing of the 336 billion raw data samples from the High Frequency Instrument (HFI) which we performed to produce six temperature maps from the first 295 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143, 217, 353, 545 and 857 GHz with an angular resolution ranging from 9.9 to 4.4′.

The white noise level is around 1.5 μK degree or less in the 3 main CMB channels (100-217 GHz). The photometric accuracy is better than 2% at frequencies between 100 and 353 GHz and around 7% at the two highest frequencies. The maps created by the HFI Data Processing Centre reach our goals in terms of sensitivity, resolution, and photometric accuracy.

They are already sufficiently accurate and well-characterised to allow scientific analyses which are presented in an accompanying series of early papers. At this stage, HFI data appears to be of high quality and we expect that with further refinements of the data processing we should be able to achieve, or exceed, the science goals of the Planck project. © ESO, 2011.

Language: English
Publisher: EDP Sciences
Year: 2011
Pages: A6
ISSN: 14320746 and 00046361
Types: Journal article and Preprint article
DOI: 10.1051/0004-6361/201116462
ORCIDs: Nørgaard-Nielsen, Hans Ulrik

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis