Journal article

Electric field concentration in hydrogel-elastomer devices

From

Department of Chemical and Biochemical Engineering, Technical University of Denmark1

The Danish Polymer Centre, Department of Chemical and Biochemical Engineering, Technical University of Denmark2

Harvard University3

Hydrogels and elastomers are being integrated to make stretchable, transparent, electromechanical devices. In such a device, a dielectric elastomer functions as an electric insulator, and a salt-containing hydrogel functions as an electric conductor. Here we report several experimental observations associated with electric field concentration along the edges of the hydrogels.

We apply cyclic voltage to a large number of samples, and record the numbers of cycles when the elastomer suffers electric breakdown. In most samples, the elastomer breaks down at the edges of the hydrogels. Before the elastomer breaks down, we observe salting out, localized heating, and plasma along the edges of the hydrogels.

These observations are consistent with the hypothesis that the concentrated electric field at the edges of the hydrogels breaks down the air when the elastomer is intact. Remarkably, the breakdown of air makes the electric field less concentrated, and protects the elastomer. When the sample is coated with an elastomer, air no longer breaks down, but the elastomer breaks down at a reduced applied voltage.

We discuss the significance of these observations in applications.

Language: English
Year: 2020
Pages: 100597
ISSN: 23524316
Types: Journal article
DOI: 10.1016/j.eml.2019.100597
ORCIDs: Vaicekauskaite, Justina , Skov, Anne Ladegaard and 0000-0002-4068-4844

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis