About

Log in?

DTU users get better search results including licensed content and discounts on order fees.

Anyone can log in and get personalized features such as favorites, tags and feeds.

Log in as DTU user Log in as non-DTU user No thanks

DTU Findit

Journal article

Carborne Gamma-Ray Spectrometry. Calibration and Applications

From

Measurement & Instrumentation, Department of Electrical Engineering, Technical University of Denmark1

Department of Electrical Engineering, Technical University of Denmark2

Department of Automation, Technical University of Denmark3

Calibration of carborne gamma-ray spectrometry systems for 137Cs is carried out with a source successively placed at 791 positions within an area of 34m  62m. A computer model supplements the measurements. Hereby a sensitivity map for a surface contamination is generated as well as line and area sensitivities.

Another model converts surface sensitivity to sensitivity for a deep contamination. Use of the sensitivity map for a non-homogeneous distribution of 137Cs is demonstrated. Applications of line sensitivities for special tasks are discussed.

Language: English
Year: 2006
Pages: 948-956
ISSN: 18729800 and 09698043
Types: Journal article
DOI: 10.1016/j.apradiso.2006.03.013

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis