About

Log in?

DTU users get better search results including licensed content and discounts on order fees.

Anyone can log in and get personalized features such as favorites, tags and feeds.

Log in as DTU user Log in as non-DTU user No thanks

DTU Findit

Journal article

The diagnostic value of exercise echocardiography in ischemic heart disease in relation to quantitative coronary arteriography

From

Risø National Laboratory for Sustainable Energy, Technical University of Denmark1

The aim of the study was to assess the diagnostic value of bicycle exercise echocardiography using quantitative coronary arteriography as a reference. Exercise echocardiography was performed in 70 consecutive patients referred for coronary angiography. Digital loops were obtained at rest, peak, and immediately after exercise in the standard views (parasternal long and short axis, apical two and four chamber views).

Wall motion analysis was made on the basis of the 16 segment model, scoring each segment from 3 (hyperkinesia) to -1 (hypokinesia). Exercise echocardiography was considered positive when wall motion in at least one segment decreased at least one score from rest to peak or post exercise. Cinefilms were evaluated using automated quantitative coronary arteriography software.

Transstenotic pressure gradients were calculated based on flow assumptions at the maximal stenosis flow reserve. Pressure losses > 30 mmHg and quantitatively measured percent diameter stenosis of > 50% were considered clinically significant. Stenoses in the equivocal range of 40-69% were subjected to separate analysis.

Exercise echocardiography was superior to exercise-induced ST-segment depression in the diagnosis of coronary artery disease. In the overall sample of 70 patients, the sensitivity of exercise echocardiography against percent diameter stenosis was 84%, against pressure gradient 86%. The specificity against these two parameters was 86% and 84%, respectively.

When analysing the subgroup of 40-69% stenoses (N = 14), sensitivity of exercise echocardiography against percent diameter stenosis was 67%, against pressure gradient 88%. The specificity against these two parameters was 100% and 84%, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

Language: English