Calculation of Leakage Inductance for High Frequency Transformers
Frequency dependent leakage inductance is often observed. High frequency eddy current effects cause a reduction in leakage inductance. The proximity effect between adjacent layers is responsible for the reduction of leakage inductance. This paper gives a detailed analysis of high frequency leakage inductance and proposes an accurate prediction methodology.
High frequency leakage inductances in several interleaved winding configurations are also discussed. Interleaved winding configurations actually give a smaller degree of reduction of leakage induction at high frequency. Finite Element Analysis (FEA) simulation and measurement validate the models.
Language: | English |
---|---|
Publisher: | IEEE |
Year: | 2015 |
Pages: | 5769-5775 |
ISSN: | 19410107 and 08858993 |
Types: | Journal article |
DOI: | 10.1109/TPEL.2014.2382175 |
ORCIDs: | Ouyang, Ziwei |
Conductors Frequency measurement High frequency Inductance Inductance measurement Magnetic cores Magnetic fields Windings eddy currents finite element analysis finite-element analysis simulation frequency-dependent leakage inductance high frequency high-frequency eddy current effects high-frequency transformers inductance measurement interleaved winding interleaved winding configurations leakage inductance leakage induction magnetic field strength power transformers prediction methodology transformer transformer windings