About

Log in?

DTU users get better search results including licensed content and discounts on order fees.

Anyone can log in and get personalized features such as favorites, tags and feeds.

Log in as DTU user Log in as non-DTU user No thanks

DTU Findit

Journal article

Deformable trailing edge flaps for modern megawatt wind turbine controllers using strain gauge sensors

From

Aeroelastic Design, Wind Energy Division, Risø National Laboratory for Sustainable Energy, Technical University of Denmark1

Wind Energy Division, Risø National Laboratory for Sustainable Energy, Technical University of Denmark2

Risø National Laboratory for Sustainable Energy, Technical University of Denmark3

The present work contains a deformable trailing edge flap controller integrated in a numerically simulated modern, variablespeed, pitch-regulated megawatt (MW)-size wind turbine. The aeroservoelastic multi-body code HAWC2 acts as a component in the control loop design. At the core of the proposed controller, all unsteady loads are divided by frequency content.

Blade pitching and generator moment react to low-frequency excitations, whereas flaps deal with high-frequency excitations. The present work should be regarded as an investigation into the fatigue load reduction potential when applying trailing edge flaps on a wind turbine blade rather than a conclusive control design with traditional issues like stability and robustness fully investigated.

Recent works have shown that the fatigue load reduction by use of trailing edge flaps may be greater than for traditional pitch control methods. By enabling the trailing edge to move independently and quickly along the spanwise position of the blade, local small flutuations in the aerodynamic forces can be alleviated by deformation of the airfoil flap.

Strain gauges are used as input for the flap controller, and the effect of placing strain gauges at various radial positions on the blade is investigated. An optimization routine minimizes blade root fatigue loads. Calculations are based on the 5 MW reference wind turbine part of the UpWind project primarily with a mean turbulent wind speed close to rated power.

A fatigue load reduction of 25% in the blade root moment was obtained for a continuous 6.3 m long flap. Copyright © 2009 John Wiley & Sons, Ltd.

Language: English
Year: 2010
Pages: 193-206
ISSN: 10991824 and 10954244
Types: Journal article
DOI: 10.1002/we.371
ORCIDs: Gaunaa, Mac , Bak, Christian and Buhl, Thomas

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis