About

Log in?

DTU users get better search results including licensed content and discounts on order fees.

Anyone can log in and get personalized features such as favorites, tags and feeds.

Log in as DTU user Log in as non-DTU user No thanks

DTU Findit

Journal article

Interobserver delineation variation in lung tumour stereotacticbody radiotherapy

From

Copenhagen University Hospital Herlev and Gentofte1

Department of Informatics and Mathematical Modeling, Technical University of Denmark2

Image Analysis and Computer Graphics, Department of Informatics and Mathematical Modeling, Technical University of Denmark3

Objectives In radiotherapy, delineation uncertainties are important as they contribute to systematic errors and can lead to geographical miss of the target. For margin computation, standard deviations (SDs) of all uncertainties must be included as SDs. The aim of this study was to quantify the interobserver delineation variation for stereotactic body radiotherapy (SBRT) of peripheral lung tumours using a cross-sectional study design.

Methods 22 consecutive patients with 26 tumours were included. Positron emission tomography/CT scans were acquired for planning of SBRT. Three oncologists and three radiologists independently delineated the gross tumour volume. The interobserver variation was calculated as a mean of multiple SDs of distances to a reference contour, and calculated for the transversal plane (SDtrans) and craniocaudal (CC) direction (SDcc) separately.

Concordance indexes and volume deviations were also calculated. Results Median tumour volume was 13.0 cm3, ranging from 0.3 to 60.4 cm3. The mean SDtrans was 0.15 cm (SD 0.08 cm) and the overall mean SDcc was 0.26 cm (SD 0.15 cm). Tumours with pleural contact had a significantly larger SDtrans than tumours surrounded by lung tissue.

Conclusions The interobserver delineation variation was very small in this systematic cross-sectional analysis, although significantly larger in the CC direction than in the transversal plane, stressing that anisotropic margins should be applied. This study is the first to make a systematic cross-sectional analysis of delineation variation for peripheral lung tumours referred for SBRT, establishing the evidence that interobserver variation is very small for these tumours.

Language: English
Publisher: The British Institute of Radiology.
Year: 2012
Pages: e654-e660
ISSN: 1748880x , 00071285 and 03062120
Types: Journal article
DOI: 10.1259/bjr/76424694
ORCIDs: 0000-0002-3523-382X and 0000-0002-3363-3256

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis