Effect of energy renovation on indoor air quality in multifamily residential buildings in Slovakia

From

Slovak University of Technology in Bratislava1

Department of Civil Engineering, Technical University of Denmark2

Section for Indoor Climate and Building Physics, Department of Civil Engineering, Technical University of Denmark3

Swedish Environmental Research Institute4

RISE Research Institutes of Sweden5

Buildings are responsible for a substantial portion of the global energy consumption. Most of the multifamily residential buildings built in the 20th century in Central and Eastern Europe do not satisfy the current requirements on energy efficiency. Nationwide measures taken to improve the energy efficiency of these buildings rarely consider their impact on the indoor air quality (IAQ).

The objective of the present study was to evaluate the impact of simple energy renovation on IAQ, air exchange rates (AER) and occupant satisfaction in Slovak residential buildings. Three pairs of identical naturally ventilated multifamily residential buildings were examined. One building in each pair was newly renovated, the other was in its original condition.

Temperature, relative humidity (RH) and the concentration of carbon dioxide (CO2) were measured in 94 apartments (57%) during one week in the winter. A questionnaire related to perceived air quality, sick building syndrome symptoms and airing habits was filled by the occupants. In a companion experiment, the IAQ was investigated in 20 apartments (50%) of a single residential building before and after its renovation.

In this experiment, concentrations of nitrogen dioxide (NO2), formaldehyde and total and individual volatile organic compounds (VOC) were also measured. CO2 concentrations were significantly higher and AERs were lower in the renovated buildings. Formaldehyde concentrations increased after renovation and were positively correlated with CO2 and RH.

Energy renovation was associated with lower occupant satisfaction with IAQ. Energy retrofitting efforts should be complemented with improved ventilation in order to avoid adverse effects on IAQ.

Language: English
Year: 2017
Pages: 363-372
ISSN: 1873684x and 03601323
Types: Journal article
DOI: 10.1016/j.buildenv.2017.06.009
ORCIDs: Bekö, Gabriel

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis