About

Log in?

DTU users get better search results including licensed content and discounts on order fees.

Anyone can log in and get personalized features such as favorites, tags and feeds.

Log in as DTU user Log in as non-DTU user No thanks

DTU Findit

Journal article

Evaluation of an enzyme-linked immunosorbent assay for serological surveillance of infection with Actinobacillus pleuropneumoniae serotype 5 in pig herds

From

Section for Veterinary Diagnostics, Division of Veterinary Diagnostics and Research, National Veterinary Institute, Technical University of Denmark1

Division of Veterinary Diagnostics and Research, National Veterinary Institute, Technical University of Denmark2

National Veterinary Institute, Technical University of Denmark3

Division of Microbiology and Risk Assessment, National Food Institute, Technical University of Denmark4

National Food Institute, Technical University of Denmark5

Secretariat, Division of Veterinary Diagnostics and Research, National Veterinary Institute, Technical University of Denmark6

An indirect enzyme-linked immunoassay for serological surveillance of infection of pigs with Actinobacillus pleuropneumoniae (Ap) serotype 5 was developed. The antigen used was prepared from Ap serotype 5b strain L20. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) analysis showed that the antigen contained high molecular weight lipopolysaccharide (LPS) and presumably also capsular polysaccharide (CP).

The Ap serotype 5 ELISA was tested using sera from pigs experimentally infected with the 12 different Ap serotypes of biotype 1 and with sera from herds naturally infected with Ap serotypes 5, 6, 7 and 12. Cross-reactions were shown in one pig from a herd naturally infected with Ap serotype 7 and in one pig from a herd naturally infected with Ap serotype 12.

The herd sensitivities of the Ap5 ELISA and a complement fixation test (CFT) were both estimated to 1.0, on the basis of serum samples from six herds naturally infected with Ap serotype 5. The herd specificities of both tests were estimated to 0.98, based on serum samples from 123 pig herds (10 samples from each herd) from the Danish specific pathogen-free (SPF) programme for pig production.

Language: English
Year: 2002
Pages: 223-232
ISSN: 18732542 and 03781135
Types: Journal article
DOI: 10.1016/s0378-1135(02)00111-6
ORCIDs: Andresen, Lars Ole

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis