About

Log in?

DTU users get better search results including licensed content and discounts on order fees.

Anyone can log in and get personalized features such as favorites, tags and feeds.

Log in as DTU user Log in as non-DTU user No thanks

DTU Findit

Journal article

A comparative performance analysis of zero voltage switching class e and selected enhanced class E inverters

From

Green University of Bangladesh1

North South University2

Department of Mechanical Engineering, Technical University of Denmark3

Acoustic Technology, Department of Electrical Engineering, Technical University of Denmark4

Manufacturing Engineering, Department of Mechanical Engineering, Technical University of Denmark5

University of Dhaka6

Department of Applied Mathematics and Computer Science, Technical University of Denmark7

This paper presents a comparative analysis of the class E and selected enhanced class E inverters, namely, the second and third harmonic group of class EFn, E/Fn and the class E Flat Top inverter. The inverters are designed under identical specifications and evaluated against the variation of switching frequency (f), duty ratio (D), capacitance ratio (k), and the load resistance (RL).

To offer a comparative understanding, the performance parameters, namely, the power output capability, efficiency, peak switch voltage and current, peak resonant capacitor voltages, and the peak current in the lumped network, are determined quantitatively. It is found that the class EF2 and E/F3 inverters, in general, have higher efficiency and comparable power output capability with respect to the class E inverter.

More specifically, the class EF2 (parallel LC and in series to the load network) and E/F3 (parallel LC and in series to the load network) maintain 90% efficiency compared to 80% for class E inverter at the optimum operating condition. Furthermore, the peak switch voltage and current in these inverters are on average 20–30% lower than the class E and other versions for k > 1.

The analysis also shows that the class EF2 and E/F3 inverters should be operated in the stretch of 1 < k < 5 and D = 0.3–0.6 at the optimum load to sustain the high-performance standard.

Language: English
Publisher: MDPI AG
Year: 2021
Pages: 2226
ISSN: 20799292
Types: Journal article
DOI: 10.3390/electronics10182226
ORCIDs: Islam, Aminul , Shihavuddin, A. S.M. , 0000-0002-8741-1245 , 0000-0003-2429-4851 and 0000-0003-0779-8820

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis