Optimization of Synthetic Aperture Image Quality

In Proceedings of Spie 2016, Volume 9790, pp. 97900Z-97900Z-9
From

Department of Electrical Engineering, Technical University of Denmark1

Biomedical Engineering, Department of Electrical Engineering, Technical University of Denmark2

Center for Fast Ultrasound Imaging, Centers, Technical University of Denmark3

Synthetic Aperture (SA) imaging produces high-quality images and velocity estimates of both slow and fast flow at high frame rates. However, grating lobe artifacts can appear both in transmission and reception. These affect the image quality and the frame rate. Therefore optimization of parameters effecting the image quality of SA is of great importance, and this paper proposes an advanced procedure for optimizing the parameters essential for acquiring an optimal image quality, while generating high resolution SA images.

Optimization of the image quality is mainly performed based on measures such as F-number, number of emissions and the aperture size. They are considered to be the most contributing acquisition factors in the quality of the high resolution images in SA. Therefore, the performance of image quality is quantified in terms of full-width at half maximum (FWHM) and the cystic resolution (CTR).

The results of the study showed that SA imaging with only 32 emissions and maximum sweep angle of 22 degrees yields a very good image quality compared with using 256 emissions and the full aperture size. Therefore the number of emissions and the maximum sweep angle in the SA can be optimized to reach a reasonably good performance, and to increase the frame rate by lowering the required number of emissions.

All the measurements are performed using the experimental SARUS scanner connected to a λ/2-pitch transducer. A wire phantom and a tissue mimicking phantom containing anechoic cysts are scanned using the optimized parameters for the transducer. Measurements coincide with simulations.

Language: English
Publisher: SPIE - International Society for Optical Engineering
Year: 2016
Pages: 97900Z-97900Z-9
Proceedings: SPIE Medical Imaging 2016
ISBN: 9781510600256
ISSN: 1996756x , 0277786x , 24109045 and 16057422
Types: Conference paper
DOI: 10.1117/12.2216506
ORCIDs: Moshavegh, Ramin , Jensen, Jonas , Villagómez Hoyos, Carlos Armando , Stuart, Matthias Bo and Jensen, Jørgen Arendt