On the importance of grain size in luminescence dating using quartz

From

Babes-Bolyai University1

Center for Nuclear Technologies, Technical University of Denmark2

Radiation Physics, Center for Nuclear Technologies, Technical University of Denmark3

Wageningen University & Research4

Victor Babes National Institute5

Chinese Academy of Sciences6

Aberystwyth University7

There are two major problems commonly encountered when applying Optically Stimulated Luminescence (OSL) dating in the high dose range: (i) age discrepancy between different grain sizes, and (ii) age underestimation. A marked and systematic discrepancy between fine-grain (4-11 μm) and coarse-grain (63-90 μm) quartz single aliquot regeneration protocol (SAR) ages has been reported previously for Romanian and Serbian loess >40 ka (De of ∼100 Gy), generally with fine-grain ages underestimating the depositional age.

In this paper, we show a similar age pattern for two grain size fractions from Chinese loess, thus pointing to a potential worldwide phenomenon. While age underestimation is often attributed to signal saturation problems, this is not the case for fine grain material, which saturates at higher doses than coarse grains, yet begins to underestimate true ages earlier.

Here we examine the dose response curves of quartz from different sedimentary contexts around the world, using a range of grain sizes (diameters of 4-11 μm, 11-30 μm, 35-50 μm, 63-90μm, 90-125μm, 125-180 μm, and 180-250 μm). All dose response curves can be adequately described by a sum of two saturating exponential functions, whose saturation characteristics (D0 values) are clearly anticorrelated with grain diameter (φ) through an inverse square root relationship, D0 = A/√φ, where A is a scaling factor.

While the mechanism behind this grain-size dependency of saturation characteristics still needs to be understood, our results show that the observation of an extended SAR laboratory dose response curve does not necessarily enable high doses to be recorded accurately, or provide a corresponding extended age range.

Language: English
Year: 2017
Pages: 464-471
ISSN: 18790925 and 13504487
Types: Journal article
DOI: 10.1016/j.radmeas.2017.01.009
ORCIDs: 0000-0001-5559-1862 , Buylaert, Jan-Pieter and Jain, M.