Efficient modulation of the magnetocaloric refrigerator capacity

From

Department of Energy Conversion and Storage, Technical University of Denmark1

Continuum Modelling and Testing, Department of Energy Conversion and Storage, Technical University of Denmark2

Thermal Energy, Department of Civil and Mechanical Engineering, Technical University of Denmark3

Department of Civil and Mechanical Engineering, Technical University of Denmark4

Functional Oxides, Department of Energy Conversion and Storage, Technical University of Denmark5

Magnetocaloric energy conversion devices (e.g., room air conditioners and household refrigerators) have the potential to significantly reduce the emissions associated with refrigerant leakage into the atmosphere but still have lower efficiencies compared to mature vapor compression systems. The efficiency of a magnetocaloric cooling device derives not only from its design characteristics (e.g., solid refrigerant, hydraulic system, and magnet system) and its operating temperature span but also from its modulating capability.

Owing to the lack of experimental data regarding this topic, the advantage of modulating the cooling capacity (i.e., the part-load performance) of an active magnetic regenerator prototype is demonstrated experimentally for the first time. The capacity modulation is carried out by means of regulating both the cycle frequency of the device and the volumetric flow rate of the heat transfer fluid.

At a 14 K temperature span and a 1.4 Hz frequency, the magnetocaloric refrigerator prototype using 3.8 kg of gadolinium provided a maximum cooling capacity of 452 W with an appreciable coefficient of performance of 3.2, which corresponds to a second-law efficiency of 15.5 %. At part-load operating conditions, the device can produce a cooling capacity of 245 W with an increased second-law efficiency of 29.7 %, or a coefficient of performance of 6.2, making it more competitive with traditional vapor compression systems.

In future studies, the experimental data obtained may be implemented in a dynamic building energy model to quantify the energy-saving benefits of part-load operation by estimating the overall system efficiency during a typical cooling season.

Language: English
Year: 2023
Pages: 59-67
ISSN: 18792081 and 01407007
Types: Journal article
DOI: 10.1016/j.ijrefrig.2022.10.005
ORCIDs: Masche, M. , Liang, J. , Engelbrecht, K. and Bahl, C.R.H.

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis