Development and verification of printed circuit board toroidal transformer model
An analytical model of an air core printed circuit board embedded toroidal transformer configuration is presented. The transformer has been developed for galvanic isolation of very high frequency switch-mode dc-dc power converter applications. The theoretical model is developed and verified by comparing calculated parameters with 3D finite element simulations and experimental measurement results.
The developed transformer model shows good agreement with the simulated and measured results. The model can be used to predict the parameters of printed circuit board toroidal transformer configurations with a maximum deviation of approximately 22%.
Language: | English |
---|---|
Publisher: | IEEE |
Year: | 2013 |
Pages: | 1654-1659 |
Proceedings: | 2013 28th Annual IEEE Applied Power Electronics Conference and Exposition |
Series: | I E E E Applied Power Electronics Conference and Exposition. Conference Proceedings |
ISBN: | 1467343536 , 1467343544 , 9781467343534 , 9781467343541 , 1467343552 and 9781467343558 |
ISSN: | 10482334 and 24706647 |
Types: | Conference paper |
DOI: | 10.1109/APEC.2013.6520519 |
ORCIDs: | Knott, Arnold |