About

Log in?

DTU users get better search results including licensed content and discounts on order fees.

Anyone can log in and get personalized features such as favorites, tags and feeds.

Log in as DTU user Log in as non-DTU user No thanks

DTU Findit

Journal article

Quantifying signal changes in nano-wire based biosensors

In Nanoscale 2011, Volume 3, Issue 2, pp. 706-717
From

University of Copenhagen1

Nano-Bio Integrated Systems Group, Biomedical Micro Systems Section, Department of Micro- and Nanotechnology, Technical University of Denmark2

Biomedical Micro Systems Section, Department of Micro- and Nanotechnology, Technical University of Denmark3

Department of Micro- and Nanotechnology, Technical University of Denmark4

Theoretical Nanoelectronics Group, Theory Section, Department of Micro- and Nanotechnology, Technical University of Denmark5

Theory Section, Department of Micro- and Nanotechnology, Technical University of Denmark6

In this work, we present a computational methodology for predicting the change in signal (conductance sensitivity) of a nano-BioFET sensor (a sensor based on a biomolecule binding another biomolecule attached to a nano-wire field effect transistor) upon binding its target molecule. The methodology is a combination of the screening model of surface charge sensors in liquids developed by Brandbyge and co-workers [Sørensen et al., Appl.

Phys. Lett., 2007, 91, 102105], with the PROPKA method for predicting the pH-dependent charge of proteins and protein-ligand complexes, developed by Jensen and co-workers [Li et al., Proteins: Struct., Funct., Bioinf., 2005, 61, 704-721, Bas et al., Proteins: Struct., Funct., Bioinf., 2008, 73, 765-783].

The predicted change in conductance sensitivity based on this methodology is compared to previously published data on nano-BioFET sensors obtained by other groups. In addition, the conductance sensitivity dependence from various parameters is explored for a standard wire, representative of a typical experimental setup.

In general, the experimental data can be reproduced with sufficient accuracy to help interpret them. The method has the potential for even more quantitative predictions when key experimental parameters (such as the charge carrier density of the nano-wire or receptor density on the device surface) can be determined (and reported) more accurately. © 2011 The Royal Society of Chemistry.

Language: English
Year: 2011
Pages: 706-717
ISSN: 20403372 and 20403364
Types: Journal article
DOI: 10.1039/c0nr00442a
ORCIDs: Brandbyge, Mads , 0000-0002-2821-5711 , 0000-0002-4639-5314 , 0000-0003-0932-8080 and 0000-0002-1465-1010

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis