About

Log in?

DTU users get better search results including licensed content and discounts on order fees.

Anyone can log in and get personalized features such as favorites, tags and feeds.

Log in as DTU user Log in as non-DTU user No thanks

DTU Findit

Journal article

Characterization of a continuous agitated cell reactor for oxygen dependent biocatalysis : Biocatalytic Oxidation in a Continuous Agitated Cell Reactor

From

Department of Chemical and Biochemical Engineering, Technical University of Denmark1

CAPEC-PROCESS, Department of Chemical and Biochemical Engineering, Technical University of Denmark2

AM Technology3

Biocatalytic oxidation reactions employing molecular oxygen as the electron acceptor are difficult to conduct in a continuous flow reactor because of the requirement for high oxygen transfer rates. In this paper, the oxidation of glucose to glucono-1,5-lactone by glucose oxidase was used as a model reaction to study a novel continuous agitated cell reactor (ACR).

The ACR consists of ten cells interconnected by small channels. An agitator is placed in each cell, which mixes the content of the cell when the reactor body is shaken by lateral movement. Based on tracer experiments, a hydrodynamic model for the ACR was developed. The model consisted of ten tanks-in-series with back-mixing occurring within and between each cell.

The back-mixing was a necessary addition to the model in order to explain the observed phenomenon that the ACR behaved as two continuous stirred tank reactors (CSTRs) at low flow rates, while it at high flow rates behaved as the expected ten CSTRs in series. The performance of the ACR was evaluated by comparing the steady state conversion at varying residence times with the conversion observed in a stirred batch reactor of comparable size.

It was found that the ACR could more than double the overall reaction rate, which was solely due to an increased oxygen transfer rate in the ACR caused by the intense mixing as a result of the spring agitators. The volumetric oxygen transfer coefficient, kL a, was estimated to be 344 h-1 in the 100 mL ACR, opposed to only 104 h-1 in a batch reactor of comparable working volume.

Interestingly, the large deviation from plug flow behavior seen in the tracer experiments was found to have little influence on the conversion in the ACR, since both a plug flow reactor (PFR) model and the backflow cell model described the data sufficiently well. Biotechnol. Bioeng. 2017;9999: 1-9. © 2017 Wiley Periodicals, Inc.

Language: English
Year: 2017
Pages: 1222-1230
ISSN: 10970290 and 00063592
Types: Journal article
DOI: 10.1002/bit.26267
ORCIDs: Pedersen, Asbjørn Toftgaard , Teresa de Melo Machado Simoes Carvalho, Ana and Woodley, John

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis