About

Log in?

DTU users get better search results including licensed content and discounts on order fees.

Anyone can log in and get personalized features such as favorites, tags and feeds.

Log in as DTU user Log in as non-DTU user No thanks

DTU Findit

Journal article

WHEN Fluorescence is not a particle: The tissue translocation of microplastics in Daphnia magna seems an artIfact

From

Goethe University Frankfurt1

Department of Environmental Engineering, Technical University of Denmark2

Environmental Fate & Effect of Chemicals, Department of Environmental Engineering, Technical University of Denmark3

Norwegian University of Science and Technology4

Previous research reported the translocation of nano- and microplastics from the gastrointestinal tract to tissues in Daphnia magna, most prominently of fluorescent polystyrene (PS) beads to lipid droplets. For particles > 300 nm, such transfer is biologically implausible as the peritrophic membrane retains these in the daphnid gut.

Thus, we aim at replicating the key study by Rosenkranz et al. (2009). We used confocal laser scanning microscopy to study the tissue transfer applying the original setup (neonates exposed to 20 and 1,000 nm PS beads at 2 µg L-1 for 4 and 24 h), the same setup with a fructose-based clearing, and a setup with a 1,000-fold higher concentration (2 mg L-1 ).

We used passive sampling to investigate whether the beads leach the fluorescent dye. While the 1,000 nm beads were visible in the gut at both exposure concentrations, the 20 nm beads were detectable at 2 mg L-1 , only. At this concentration, we observed fluorescence in lipid droplets in daphnids exposed to both particle types.

However, this did not co-localize with the 1,000 nm beads which remained visible in the gut. We further confirmed the leaching of the fluorescent dye using a passive sampler, a method that can also be applied in future studies. In summary, we cannot replicate the original study but demonstrate that the fluorescence in the lipid droplets of D. magna results from leaching of the dye.

Thus, the use of fluorescence as a surrogate for particles can lead to artifacts in uptake and translocation studies. This highlights the need to confirm the stability of the fluorescence label or to localize particles using alternative methods. 

Language: English
Year: 2019
Pages: 1495-1503
ISSN: 15528618 and 07307268
Types: Journal article
DOI: 10.1002/etc.4436
ORCIDs: Rist, Sinja , Baun, Anders , Mayer, Philipp , Hartmann, Nanna B. , 0000-0001-5865-980X and 0000-0002-4402-3234

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis