About

Log in?

DTU users get better search results including licensed content and discounts on order fees.

Anyone can log in and get personalized features such as favorites, tags and feeds.

Log in as DTU user Log in as non-DTU user No thanks

DTU Findit

Journal article

Micro-flow-injection analysis (μFIA) immunoassay of herbicide residue 2,6-dichlorobenzamide: towards automated at-line monitoring using modular microfluidics

In Analyst 2015, Volume 140, Issue 5, pp. 1616-1623
From

Department of Micro- and Nanotechnology, Technical University of Denmark1

Surface Engineering, Department of Micro- and Nanotechnology, Technical University of Denmark2

Bioanalytics, Department of Micro- and Nanotechnology, Technical University of Denmark3

Geological Survey of Denmark and Greenland4

DHI Water - Environment - Health5

Fluidic Array Systems and Technology, Department of Micro- and Nanotechnology, Technical University of Denmark6

As a part of developing new systems for continuously monitoring the presence of pesticides in groundwater, a microfluidic amperometric immunosensor was developed for detecting the herbicide residue 2,6-dichlorobenzamide (BAM) in water. A competitive immunosorbent assay served as the sensing mechanism and amperometry was applied for detection.

Both the immunoreaction chip (IRC) and detection (D) unit are integrated on a modular microfluidic platform with in-built micro-flow-injection analysis (μFIA) function. The immunosorbent, immobilized in the channel of the IRC, was found to have high long-term stability and withstand many regeneration cycles, both of which are key requirements for systems utilized in continuous monitoring.

The IRC was regenerated during 51 cycles in a heterogeneous competitive assay out of which 27 were without the analyte (the highest possible signal level) in order to assess the regeneration capability of the immunosorbent. Detection of BAM standard solutions was performed in the concentration range from 62.5 μg L−1 to 0.0008 μg L−1.

Non-linear regression of the data using the four-parameter logistic equation generated a sigmoidal standard curve showing an IC50 value (concentration that reduces the signal by 50%) of 0.25 μg L−1. The strongest signal variation is observed in the concentration range between 0.02 and 2.5 μg L−1, which includes the 0.1 μg L−1 threshold limit set by the European Commission for BAM in drinking water.

The presented results demonstrate the potential of the constructed μFIA immunosensor as an at-line monitoring system for controlling the quality of ground water supply.

Language: English
Publisher: The Royal Society of Chemistry
Year: 2015
Pages: 1616-1623
ISSN: 13645528 and 00032654
Types: Journal article
DOI: 10.1039/c4an01576b
ORCIDs: Heiskanen, Arto , Dufva, Martin and Jakobsen, Mogens Havsteen

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis