Effect of pre-oxidation on the oxidation resistance of Crofer 22 APU

From

Department of Energy Conversion and Storage, Technical University of Denmark1

Mixed Conductors, Department of Energy Conversion and Storage, Technical University of Denmark2

Norwegian University of Science and Technology3

The ferritic stainless steel Crofer 22 APU is attractive for the use as interconnects in solid oxide fuel cell stacks. The oxidation rate of this alloy in air at 800 °C was reduced by pre-oxidation at higher temperatures in either air or N2-9%H2-1%H2O. Conversely, the oxidation rate increased when the alloy grain size was increased by heat-treating in H2 (pO2 ∼ 10−21 atm).

In all cases the scale formed on Crofer 22 APU consisted of an outer (Mn,Cr)3O4 layer, an inner Cr2O3 layer and sub-scale MnCr2O4 nodules that preferentially formed at alloy grain boundaries.

Language: English
Year: 2018
Pages: 189-199
ISSN: 18790496 and 0010938x
Types: Journal article
DOI: 10.1016/j.corsci.2018.04.016
ORCIDs: Talic, Belma , Molin, Sebastian and Hendriksen, Peter Vang