Functionalization of SU-8 Photoresist Surfaces with IgG Proteins

From

Nanoprobes Group, NanoSystemsEngineering Section, Department of Micro- and Nanotechnology, Technical University of Denmark1

NanoSystemsEngineering Section, Department of Micro- and Nanotechnology, Technical University of Denmark2

Department of Micro- and Nanotechnology, Technical University of Denmark3

Fluidic Array Systems and Technology Group, Biomedical Micro Systems Section, Department of Micro- and Nanotechnology, Technical University of Denmark4

Biomedical Micro Systems Section, Department of Micro- and Nanotechnology, Technical University of Denmark5

The negative epoxy-based photoresist SU-8 has a variety of applications within microelectromechanical systems (MEMS) and lab-on-a-chip systems. Here, several methods to functionalize SU-8 surfaces with IgG proteins were investigated. Fluorescent labeled proteins and fluorescent sandwich immunoassays were employed to characterize the binding efficiency of model proteins to bare SU-8 surface, SU-8 treated with cerium ammonium nitrate (CAN) etchant and CAN treated surfaces modified by aminosilanization.

The highest binding capacity of antibodies was observed on bare SU-8. This explains why bare SU-8 in a functional fluorescent sandwich immunoassay detecting C-reactive protein (CRP) gave twice as high signal as compared with the other two surfaces. Immunoassays performed on bare SU-8 and CAN treated SU-8 resulted in detection limits of CRP of 30 and 80 ng/ml respectively which is sufficient for detecting CRP in clinical samples, where concentrations of 3–10 μg/ml are normal for healthy individuals.

In conclusion, bare SU-8 and etched SU-8 can be modified with antibodies by a simple adsorption procedure which simplifies building lab-on-a-chip systems in SU-8. Additionally, we report the fabrication process and use of microwells created in a SU-8 layer with the same dimensions as a standard microscope glass slide that could fit into fluorescent scanners.

The SU-8 microwells minimize the reagent consumption and are straightforward to handle compared to SU-8 coated microscope slides.

Language: English
Year: 2008
Pages: 2896-2902
ISSN: 18735584 and 01694332
Types: Journal article
DOI: 10.1016/j.apsusc.2008.08.089
ORCIDs: Keller, Stephan Urs , Boisen, Anja and Dufva, Hans Martin

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis