About

Log in?

DTU users get better search results including licensed content and discounts on order fees.

Anyone can log in and get personalized features such as favorites, tags and feeds.

Log in as DTU user Log in as non-DTU user No thanks

DTU Findit

Journal article

Complementarity of a photon-counting system and radioscopy for inspection of cast aluminium components

From

Risø National Laboratory for Sustainable Energy, Technical University of Denmark1

This study aims at establishing X-ray methods for inspection of cast aluminium components by combining two approaches, a radioscopic inspection, and a photon-counting system.Indeed, radioscopy is widely used in castings inspection for automatic defect detection and is an efficient method for characterising rather small thicknesses, typically less than 40mm.

However, cast components often show a high range of thicknesses and imaging the whole range is difficult. We propose to use photon-counting measurements to complement the radioscopic image for high thicknesses. Photon-counting is not an imaging tool, but the thickness sensitivity obtained from photon-counting measurements (number of X-ray photons transmitted through the object) is much better than what can be obtained by classical radioscopy for up to 60mm of aluminium.

For high thicknesses of aluminium, within small volumes where defects are believed to be critical, the photon-counting system allows getting information additional to that obtained from classical radioscopy images.

Language: English
Year: 2005
Pages: 239-250
ISSN: 09638695 and 18791174
Types: Journal article
DOI: 10.1016/j.ndteint.2004.07.008