About

Log in?

DTU users get better search results including licensed content and discounts on order fees.

Anyone can log in and get personalized features such as favorites, tags and feeds.

Log in as DTU user Log in as non-DTU user No thanks

DTU Findit

Journal article

In-situ doped junctionless polysilicon nanowires field effect transistors for low-cost biosensors

From

Department of Micro- and Nanotechnology, Technical University of Denmark1

Nano Bio Integrated Systems, Department of Micro- and Nanotechnology, Technical University of Denmark2

Technical University of Denmark3

Silicon nanowire (SiNW) field effect transistor based biosensors have already been proven to be a promising tool to detect biomolecules. However, the most commonly used fabrication techniques involve expensive Silicon-On-Insulator (SOI) wafers, E-beam lithography and ion-implantation steps. In the work presented here, a top down approach to fabricate SiNW junctionless field effect biosensors using novel in-situ doped polysilicon is demonstrated.

The p-type polysilicon is grown with an optimum boron concentration that gives a good metal-silicon electrical contact while maintaining the doping level at a low enough level to provide a good sensitivity for the biosensor. The silicon nanowires are patterned using standard photolithography and a wet etch method.

The metal contacts are made from magnetron sputtered TiW and e-beam evaporation of gold. The passivation of electrodes has been done by sputtered Si3N4 which is patterned by a lift-off process. The characterization of the critical fabrication steps is done by Secondary Ion Mass Spectroscopy (SIMS) and by statistical analysis of the measurements made on the width of the SiNWs.

The electrical characterization of the SiNW in air is done by sweeping the back gate voltage while keeping the source drain potential to a constant value and surface characterization is done by applying liquid gate in phosphate buffered saline (PBS) solution. The fabricated SiNWs sensors functionalized with (3-aminopropyl)triethoxysilane (APTES) have demonstrated good sensitivity in detecting different pH buffer solutions.

Language: English
Publisher: Elsevier
Year: 2017
Pages: 88-95
ISSN: 22141804
Types: Journal article
DOI: 10.1016/j.sbsr.2016.09.001
ORCIDs: Patou, François , Svendsen, Winnie Edith , Dimaki, Maria and 0000-0002-2172-1179

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis