Development of an accumulation-based system for cost-effective chamber measurements of inert trace gas fluxes
Ecosystems, Biosystems Division, Risø National Laboratory for Sustainable Energy, Technical University of Denmark1
Biosystems Division, Risø National Laboratory for Sustainable Energy, Technical University of Denmark2
Risø National Laboratory for Sustainable Energy, Technical University of Denmark3
Centre for Ecology and Hydrology4
As soil–atmosphere fluxes of greenhouse gases are characterized by high temporal fluctuations, frequent measurements in the range of hours to days need to be deployed, resulting in high analytical costs. We have therefore developed a new low-cost system that combines high-frequency automated sampling with low-frequency chemical analysis.
The System for Inert Gas Monitoring by Accumulation (SIGMA) is suited particularly for stand-alone observations in remote locations. The SIGMA is connected to an automated chamber with headspace sampling several times per day. Air samples are aggregated in sampling bags, which reduces the number of subsequent laboratory analyses and allows calculation of average flux rates over extended sampling periods.
The SIGMA was tested under field conditions and compared with a conventional autochamber system, where flux rates were measured several times per day. Sample air fillings of the SIGMA sampling bags varied less than 5% between bags and diverged
Language: | English |
---|---|
Year: | 2010 |
Pages: | 785-792 |
ISSN: | 13652389 and 13510754 |
Types: | Journal article |
DOI: | 10.1111/j.1365-2389.2010.01272.x |