About

Log in?

DTU users get better search results including licensed content and discounts on order fees.

Anyone can log in and get personalized features such as favorites, tags and feeds.

Log in as DTU user Log in as non-DTU user No thanks

DTU Findit

Journal article

Can commonly-used fan-driven air cleaning technologies improve indoor air quality? A literature review

From

Tsinghua University1

Department of Civil Engineering, Technical University of Denmark2

Section for Indoor Environment, Department of Civil Engineering, Technical University of Denmark3

Syracuse University4

Virginia Polytechnic Institute and State University5

University of Texas at Dallas6

Central South University7

The University of Hong Kong8

Institute of Shanghai Building Science9

Air cleaning techniques have been applied worldwide with the goal of improving indoor air quality. The effectiveness of applying these techniques varies widely, and pollutant removal efficiency is usually determined in controlled laboratory environments which may not be realized in practice. Some air cleaners are largely ineffective, and some produce harmful by-products.

To summarize what is known regarding the effectiveness of fan-driven air cleaning technologies, a state-of-the-art review of the scientific literature was undertaken by a multidisciplinary panel of experts from Europe, North America, and Asia with expertise in air cleaning, aerosol science, medicine, chemistry and ventilation.

The effects on health were not examined. Over 26,000 articles were identified in major literature databases; 400 were selected as being relevant based on their titles and abstracts by the first two authors, who further reduced the number of articles to 160 based on the full texts. These articles were reviewed by the panel using predefined inclusion criteria during their first meeting.

Additions were also made by the panel. Of these, 133 articles were finally selected for detailed review. Each article was assessed independently by two members of the panel and then judged by the entire panel during a consensus meeting. During this process 59 articles were deemed conclusive and their results were used for final reporting at their second meeting.

The conclusions are that: (1) None of the reviewed technologies was able to effectively remove all indoor pollutants and many were found to generate undesirable by-products during operation. (2) Particle filtration and sorption of gaseous pollutants were among the most effective air cleaning technologies, but there is insufficient information regarding long-term performance and proper maintenance. (3) The existing data make it difficult to extract information such as Clean Air Delivery Rate (CADR), which represents a common benchmark for comparing the performance of different air cleaning technologies. (4) To compare and select suitable indoor air cleaning devices, a labeling system accounting for characteristics such as CADR, energy consumption, volume, harmful by-products, and life span is necessary.

For that purpose, a standard test room and condition should be built and studied. (5) Although there is evidence that some air cleaning technologies improve indoor air quality, further research is needed before any of them can be confidently recommended for use in indoor environments.

Language: English
Publisher: Elsevier Ltd.
Year: 2011
Pages: 4329-4343
ISSN: 18732844 and 13522310
Types: Journal article
DOI: 10.1016/j.atmosenv.2011.05.041
ORCIDs: Wargocki, Pawel and Fang, Lei
Other keywords

AC - activated carbon AC, activated carbon Air cleaner BTEX - benzene, toluene, ethyl benzene, and xylene BTEX, benzene, toluene, ethyl benzene, and xylene By-product CADR - clean air delivery rate CADR, clean air delivery rate CFM - cubic feet per minute CFM, cubic feet per minute Clean air delivery rate (CADR) DBD - dielectric barrier discharge DBD, dielectric barrier discharge EPA - Environmental Protection Agency EPA, Environmental Protection Agency ESP - electrostatic precipitator ESP, electrostatic precipitator Electrostatic precipitator HEPA - high efficiency particulate air HEPA, high efficiency particulate air High efficiency particulate air (HEPA) IAQ - indoor air quality IAQ, indoor air quality Indoor air quality (IAQ) Ion generator Ozone PCO - photocatalytic oxidation PCO, photocatalytic oxidation Photocatalytic oxidation (PCO) Plasma SOA - secondary organic aerosol SOA, secondary organic aerosol SP - submicron particles SP, submicron particles SVOC - semi-volatile organic compound SVOC, semi-volatile organic compound Sorption TCO - thermal catalytic oxidation TCO, thermal catalytic oxidation TVOC - total volatile organic compound TVOC, total volatile organic compound Thermal catalytic oxidation (TCO) UV-C - ultraviolet C, wavelength range: 280–100 nm UV-C, ultraviolet C, wavelength range: 280–100 nm UVGI - ultraviolet germicidal irradiation UVGI, ultraviolet germicidal irradiation Ultraviolet germicidal irradiation (UVGI) VOC - volatile organic compound VOC, volatile organic compound WHO - World Health Organization WHO, World Health Organization

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis