Quantifying the potential of automated dynamic solar shading in office buildings through integrated simulations of energy and daylight

From

Section for Building Physics and Services, Department of Civil Engineering, Technical University of Denmark1

Department of Civil Engineering, Technical University of Denmark2

Section for Building Design, Department of Civil Engineering, Technical University of Denmark3

The façade design is and should be considered a central issue in the design of energy-efficient buildings. That is why dynamic façade components are increasingly used to adapt to both internal and external impacts, and to cope with a reduction in energy consumption and an increase in occupant comfort.

To gain a complete picture of any façade’s performance and subsequently carry out a reasonable benchmarking of various façade alternatives, the total energy consumption and indoor environment need to be considered simultaneously. We quantified the potential of dynamic solar shading façade components by using integrated simulations that took energy demand, the indoor air quality, the amount of daylight available, and visual comfort into consideration.

Three types of façades were investigated (without solar shading, with fixed solar shading, and with dynamic solar shading), and we simulated them with various window heights and orientations. Their performance was evaluated on the basis of the building’s total energy demand, its energy demand for heating, cooling and lighting, and also its daylight factors.

Simulation results comparing the three façade alternatives show potential for significant energy reduction, but greater differences and conflicting tendencies were revealed when the energy needed for heating, cooling and artificial lighting were considered separately. Moreover, the use of dynamic solar shading dramatically improved the amount of daylight available compared to fixed solar shading, which emphasises the need for dynamic and integrated simulations early in the design process to facilitate informed design decisions about the façade.

Language: English
Year: 2011
Pages: 757-768
ISSN: 14711257 and 0038092x
Types: Journal article
DOI: 10.1016/j.solener.2011.01.010
ORCIDs: Svendsen, Svend and Bjerregaard Jensen, Lotte

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis