Uncertainty of power curve measurement with a two-beam nacelle-mounted lidar : Uncertainty of power curve measurement

In Wind Energy 2015, Volume 19, Issue 7, pp. 1269-1287
From

Department of Wind Energy, Technical University of Denmark1

Test and Measurements, Department of Wind Energy, Technical University of Denmark2

Avent Lidar Technology3

Nacelle lidars are attractive for offshore measurements since they can provide measurements of the free wind speed in front of the turbine rotor without erecting a met mast, which significantly reduces the cost of the measurements. Nacelle-mounted pulsed lidars with two lines of sight (LOS) have already been demonstrated to be suitable for use in power performance measurements.

To be considered as a professional tool, however, power curve measurements performed using these instruments require traceable calibrated measurements and the quantification of the wind speed measurement uncertainty. Here we present and demonstrate a procedure fulfilling these needs. A nacelle lidar went through a comprehensive calibration procedure.

This calibration took place in two stages. First with the lidar on the ground, the tilt and roll readings of the inclinometers in the nacelle lidar were calibrated. Then the lidar was installed on a 9m high platform in order to calibrate the wind speed measurement. The lidar’s radial wind speed measurement along each LOS was compared with the wind speed measured by a calibrated cup anemometer, projected along the LOS direction.

The various sources of uncertainty in the lidar wind speed measurement have been thoroughly determined: uncertainty of the reference anemometer, the horizontal and vertical positioning of the beam, the lack of homogeneity of the flow within the probe volume, lidar measurement mean deviation and standard uncertainty.

The resulting uncertainty lies between 1 and 2% for the wind speed range between cut-in and rated wind speed. Finally, the lidar was mounted on the nacelle of a wind turbine in order to perform a power curve measurement. The wind speed was simultaneously measured with a mast-top mounted cup anemometer placed two rotor diameters upwind of the turbine.

The wind speed uncertainty related to the lidar tilting was calculated based on the tilt angle uncertainty derived from the inclinometer calibration and the deviation of the measurement height from hub height. The resulting combined uncertainty in the power curve using the nacelle lidar was less than 10% larger on average than that obtained with the mast mounted cup anemometer.

Copyright © 2015 John Wiley & Sons, Ltd.

Language: English
Year: 2015
Pages: 1269-1287
ISSN: 10954244 and 10991824
Types: Journal article
DOI: 10.1002/we.1897
ORCIDs: Wagner, Rozenn and Courtney, Michael Stephen

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis