Motion Correction of Single-Voxel Spectroscopy by Independent Component Analysis Applied to Spectra From Nonanesthetized Pediatric Subjects : Motion Correction of SVS From Pediatric Subjects by ICA

From

Cognitive Systems, Department of Informatics and Mathematical Modeling, Technical University of Denmark1

Department of Informatics and Mathematical Modeling, Technical University of Denmark2

Biomedical Engineering, Department of Electrical Engineering, Technical University of Denmark3

Department of Electrical Engineering, Technical University of Denmark4

For single-voxel spectroscopy, the acquisition of the spectrum is typically repeated n times and then combined with a factor in order to improve the signal-to-noise ratio. In practice, the acquisitions are not only affected by random noise but also by physiologic motion and subject movements. Since the influence of physiologic motion such as cardiac and respiratory motion on the data is limited, it can be compensated for without data loss.

Individual acquisitions hampered by subject movements, on the other hand, need to be rejected if no correction or compensation is possible. If the individual acquisitions are stored, it is possible to identify and reject the motion-disturbed acquisitions before averaging. Several automatic algorithms were investigated using a dataset of spectra from nonanesthetized infants with a gestational age of 40 weeks.

Median filtering removed most subject movement artifacts, but at the cost of increased sensitivity to random noise. Neither independent component analysis nor outlier identification with multiple comparisons has this problem. These two algorithms are novel in this context. The peak height values of the metabolites were increased compared to the mean of all acquisitions for both methods, although primarily for the ICA method.

Magn Reson Med, 2009. © 2009 Wiley-Liss, Inc.

Language: English
Publisher: Wiley Subscription Services, Inc., A Wiley Company
Year: 2009
Pages: 1147-1154
ISSN: 15222594 and 07403194
Types: Journal article
DOI: 10.1002/mrm.22129
ORCIDs: Hansen, Lars Kai and Hanson, Lars G.

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis