Microstructure degradation of LSM-YSZ cathode in SOFCs operated at various conditions

From

Microstructures and Interfaces, Fuel Cells and Solid State Chemistry Division, Risø National Laboratory for Sustainable Energy, Technical University of Denmark1

Fuel Cells and Solid State Chemistry Division, Risø National Laboratory for Sustainable Energy, Technical University of Denmark2

Risø National Laboratory for Sustainable Energy, Technical University of Denmark3

Electroceramics, Fuel Cells and Solid State Chemistry Division, Risø National Laboratory for Sustainable Energy, Technical University of Denmark4

Electrochemical Evaluation, Fuel Cells and Solid State Chemistry Division, Risø National Laboratory for Sustainable Energy, Technical University of Denmark5

Systematic microstructural analyses have been carried out on a series of technological SOFCs that went through long-term cell tests with various operating parameters including temperature, current load and time length under current. For the LSM-YSZ cathode, a number of microstructure degradation mechanisms have been identified.

And it has been observed that different mechanisms dominate the degradation process under different test conditions. The severe cathode degradation at 750 °C operation with high current density is attributed to a loss of the cathode/electrolyte interface stability. For the cells tested at 850 °C, the interface stability is maintained due to further sintering during cell operation.

A cell test lasting for 2 years (17500 h) at 850 °C with a moderate current density (not greater than 1 A/cm2) has shown that the cathode microstructure is fairly robust to the degradation processes at this temperature, such as grain coarsening and element diffusion. The cell degrades mildly with a cell voltage degradation rate of 7 mV/1000 h.

Language: English
Year: 2012
Pages: 97-103
ISSN: 18727689 and 01672738
Types: Journal article
DOI: 10.1016/j.ssi.2011.10.020
ORCIDs: Thydén, Karl Tor Sune , Chen, Ming and Hagen, Anke