About

Log in?

DTU users get better search results including licensed content and discounts on order fees.

Anyone can log in and get personalized features such as favorites, tags and feeds.

Log in as DTU user Log in as non-DTU user No thanks

DTU Findit

Conference paper

Tissue motion in blood velocity estimation and its simulation

In Ieee Ultrasonics Symposium Proceeding — 1998, pp. 1495-1499
From

Department of Information Technology, Technical University of Denmark1

Copenhagen University Hospital Herlev and Gentofte2

Center for Fast Ultrasound Imaging, Centers, Technical University of Denmark3

Determination of blood velocities for color flow mapping systems involves both stationary echo cancelling and velocity estimation. Often the stationary echo cancelling filter is the limiting factor in color flow mapping and the optimization and further development of this filter is crucial to the improvement of color flow imaging.

Optimization based on in-vivo data is difficult since the blood and tissue signals cannot be accurately distinguished and the correct extend of the vessel under investigation is often unknown. This study introduces a model for the simulation of blood velocity data in which tissue motion is included.

Tissue motion from breathing, heart beat, and vessel pulsation were determined based on in-vivo RF-data obtained from 10 healthy volunteers. The measurements were taken at the carotid artery at one condition and in the liver at three conditions. Each measurement was repeated 10 times to cover the whole cardiac cycle and a total of 400 independent RF measurements of 950 pulse echo lines were recorded.

The motion of the tissue surrounding the hepatic vein from superficial breathing had a peak velocity of 6.2±3.4 mm/s over the cardiac cycle, when averaged over the 10 volunteers. The motion due to the heart, when the volunteer was asked to hold his breath, gave a peak velocity of 4.2±1.7 mm/s. The movement of the carotid artery wall due to changing blood pressure had a peak velocity of 8.9±3.7 mm/s over the cardiac cycle.

The variations are due to differences in heart rhythm, breathing, and anatomy. All three of these motions are handled independently by the simulation program, which also includes a parametric model for the pulsatile velocity in the elastic vessel. The model can be used for optimizing both color flow mapping and spectral display systems

Language: English
Publisher: IEEE
Year: 1998
Pages: 1495-1499
Proceedings: 1998 IEEE Ultrasonics Symposium
ISBN: 0780340957 and 9780780340954
Types: Conference paper
DOI: 10.1109/ULTSYM.1998.765228
ORCIDs: Jensen, Jørgen Arendt

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis