Conference paper
Effect of Chemical Environment and pH on AC Corrosion of Cathodically Protected Structures
AC corrosion of structures under cathodic protection (CP) is a major concern for pipelines in case of even minor AC perturbations. There are indications that the specific chemical environment has a large influence on the AC mitigation current density criteria outlined in EN 15280:2013 [1]. This work investigates the effect of soil constituents, the earth alkali elements Ca and Mg, believed to have a large influence on the precipitation of hydroxides and carbonates in front of a coating damage.
The formation of different polymorphous calcium carbonates, depending on the cathodic potential are observed as well as calcium hydroxides at high cathodic protection levels. This indicates a highly alkaline (pH > 11) environment locally. Corrosion rates at different cathodic potentials are measured using electrical resistance (ER) probes and a chemical and phase analysis of the calcareous deposits and corrosion products is made using scanning electron microscopy and energy dispersive x-ray spectroscopy (SEM/EDS) and x-ray diffraction (XRD).
The findings suggest an AC corrosion mechanism highly dependent on the build-up and break-down of calcareous deposits at high CP, which is clearly reflected in variations in the spread resistance.
Language: | English |
---|---|
Publisher: | NACE International |
Year: | 2017 |
Proceedings: | NACE Corrosion 2017: Conference & Expo |
ISBN: | 1510840346 and 9781510840348 |
Types: | Conference paper |