About

Log in?

DTU users get better search results including licensed content and discounts on order fees.

Anyone can log in and get personalized features such as favorites, tags and feeds.

Log in as DTU user Log in as non-DTU user No thanks

DTU Findit

Conference paper · Journal article

Validation of the dynamic wake meander model with focus on tower loads

From

Department of Wind Energy, Technical University of Denmark1

Wind turbine loads & control, Department of Wind Energy, Technical University of Denmark2

Test and Measurements, Department of Wind Energy, Technical University of Denmark3

Aerodynamic design, Department of Wind Energy, Technical University of Denmark4

This paper presents a comparison between measured and simulated tower loads for the Danish offshore wind farm Nysted 2. Previously, only limited full scale experimental data containing tower load measurements have been published, and in many cases the measurements include only a limited range of wind speeds.

In general, tower loads in wake conditions are very challenging to predict correctly in simulations. The Nysted project offers an improved insight to this field as six wind turbines located in the Nysted II wind farm have been instrumented to measure tower top and tower bottom moments. All recorded structural data have been organized in a database, which in addition contains relevant wind turbine SCADA data as well as relevant meteorological data - e.g. wind speed and wind direction - from an offshore mast located in the immediate vicinity of the wind farm.

The database contains data from a period extending over a time span of more than 3 years. Based on the recorded data basic mechanisms driving the increased loading experienced by wind turbines operating in offshore wind farm conditions have been identified, characterized and modeled. The modeling is based on the Dynamic Wake Meandering (DWM) approach in combination with the state-of-the-art aeroelastic model HAWC2, and has previously as well as in this study shown good agreement with the measurements.

The conclusions from the study have several parts. In general the tower bending and yaw loads show a good agreement between measurements and simulations. However, there are situations that are still difficult to match. One is tower loads of single-wake operation near rated ambient wind speed for single wake situations for spacing’s around 7-8D.

A specific target of the study was to investigate whether the largest tower fatigue loads are associated with a certain downstream distance. This has been identified in both simulations and measurements, though a rather flat optimum is seen in the measurements.

Language: English
Publisher: IOP Publishing
Year: 2017
Pages: 012027
Proceedings: Wake Conference 2017
Series: Journal of Physics: Conference Series
ISSN: 17426596 and 17426588
Types: Conference paper and Journal article
DOI: 10.1088/1742-6596/854/1/012027
ORCIDs: Larsen, Torben J. , Larsen, Gunner Chr. , Pedersen, Mads Mølgaard and Madsen, Helge Aagaard

DTU users get better search results including licensed content and discounts on order fees.

Log in as DTU user

Access

Analysis